The NetWall 6000 Series is designed to be installed in most standard 19-inch equipment racks. The following general guidelines for racks should be followed:
The rack or cabinet used for mounting should be adequately secured to prevent it from becoming unstable and/or falling over.
Devices installed in the rack or cabinet should be mounted as low as possible, with the heaviest devices at the bottom and progressively lighter devices installed above.
The Rack Mounting Kit
Included in the 6000 Series packaging are the following:A front bracket kit.
A side-rail kit.
The ordering of kit attachment is not important but both the components listed above should be correctly installed before mounting the NetWall 6000 Series in a rack.
The front bracket kit consists of two brackets, each of which has three screws for attachment to the front-sides of the 6000 Series, as shown in the image below. There are pre-drilled holes already in the sides of the unit which are used for attaching these brackets.
A bracket should be attached to each side of the 6000 Series casing with a screwdriver using the screws supplied.
Attaching the side-rails is described next.
The side-rail kit consists of two side-rails with screws for fitting to the sides of the NetWall 6000 Series so it can be slid into a 1U rack mount.
Using a suitable screwdriver and the screws provided, attach a rail to both sides of the NetWall 6000 Series unit. There are pre-drilled holes in the unit for this.
The unit is now ready for sliding into a rack. After positioning the unit, the front brackets should be attached to the rack so the unit cannot slide out.